Downhole Tester Valve

The downhole tester Valve is used for drill stem testing service. There are two types of downhole tester valve we supplied including select tester valve and LPR- N valve. The select tester valve is a full opening, annulus pressure operated tool used in ca
Description

Downhole Tester Valve introduction

The downhole tester Valve is used for drill stem testing service. There are two types of downhole tester valve we supplied including select tester valve and LPR- N valve. The select tester valve is a full opening, annulus pressure operated tool used in cased holes. This tool has the capabilities of taking multiple downhole closures where pipe manipulation is restricted and a full opening string is desired

 

Structure of downhole tester valve - select tester valve

 

The select tester valve is composed of four basic sections; ball valve section, upper hydraulic section, nitrogen section and the metering section.

 

* The ball valve section contains the ball valve and the mechanism that rotates the ball when the tool is activated; the ball is rotated to the open    

   position allowing the reservoir to flow into the testing string.

* The upper hydraulic section is contained between the upper annulus ports and the nitrogen filler valve. The critical part of this section is the

   metering (power) cartridge and selector.

* The nitrogen section is composed of the nitrogen case, nitrogen mandrel, floating piston and nitrogen filler valve. The nitrogen acts as an

   adjustable spring and provides the force needed to close the ball valve.

* The metering section is composed of the lower oil chamber, metering cartridge and floating piston. The oil in this section acts as a barrier

   between the tool and the annular fluid. This insures that only clean fluid passes through the metering cartridge

 

Technical parameter

 

NO. Specification 5”
1 OD 5”(127mm)
2 ID 2.25”(57mm)
3 Length(mm) 288.2”(7319.5mm)
4 Working pressure 15000 PSI(105Mpa)
5 Maximum open pressure differential 5000PSI(35Mpa)
6 Internal Pressure Strength 151Mpa
7 External Pressure Strength 141Mpa
8 Torque strength 30.9kN.m
9 Service Environment Mud, crude oil, natural gas with H2S, Apply to NACE MR0175-2003
10 End connection 3 7/8CAS. BXP, 3 1/2 IF BXP
11 Service temperature -20oF~400oF
 
Specification 5”
OD 127.5mm
ID 57mm
Length 6555mm
Working pressure 105Mpa
Ball valve Open Differential pressure 35Mpa
Ball valve top and bottom differential pressure 70Mpa
Internal Pressure strength 146Mpa
External pressure strength 136Mpa
Tensile strength 2034KN
Torque strength 31.6KN.m
Circulating Flow area 2280mm2
Service H2S,NACE MR0175(>175oF)
Working temperature -29℃~+204℃
Connection thread 3 7/8″CAS.B×P or 3 1/2″IF.B×P