OD | 1-11/16" | 2.125" | 2.75(No perforation) | 2.75"(perforation) | 3.6" |
Maximum Operating Pressure | 15000 psi (normal) 20000psi(customized) |
15000 psi (normal) 20000psi(customized) |
15000 psi (normal) 20000psi(customized) |
15000 psi (normal) 20000psi(customized) |
15000 psi (normal) 20000psi(customized) |
Maximum Operating Temperature | 135℃, 6 hours 150℃, 2 hours |
135°C [275°F] up to 6hrs, 225°C [437°F] up to 6hrs with external flask |
135°C [275°F] up to 6hrs, 225°C [437°F] up to 6hrs with external flask |
135°C [275°F] up to 6hrs, 225°C [437°F] up to 6hrs with external flask |
135°C [275°F] up to 6hrs, 225°C [437°F] up to 6hrs with external flask |
Length | 52" (132cm) | 50" (128cm) | 52" (134cm) | 48" (122cm) | 48" 122cm |
Stroke Length | 12" | 10" | 10" | 5.5" | 10" |
Material | 4140 (normal) 718 (customized) |
4140 (normal) 718 (customized) |
4140 (normal) 718 (customized) |
4140 (normal) 718 (customized) |
4140 (normal) 718 (customized) |
Nominal Force | 15000lbs 6.8t | 30000lbs,13t(常规) 45000lbs,20t(定制) |
40000lbs,18t(常规) 50000lbs,22t(定制) |
30000lbs,(常规) | 60000lbs,27t(常规) 90000lbs,40t(定制) |
Setting Rate | 0.5"/min | 0.5"/min | 0.5"/min | 2"/min | 0.5"/min |
Outside Diameter | 1-11/16" | 2.125" | 2.75" | 2.75" | 3.6" |
Stroke Time | 20min | 17min | 17min | 3min | 17min |
Bridge Releasing Time(probably) | 7-17min | 7-10min | 7-10min | 25min | 7-10min |
Operation Type | Slickline/E-Line | Slickline/E-Line | Slickline/E-Line | Slickline/E-Line | Slickline/E-Line |
PCM | Slickline module E-Line module Perforation module |
Slickline module E-Line module Perforation module |
Slickline module E-Line module Perforation module |
Slickline module E-Line module Perforation module |
Slickline module E-Line module Perforation module |
PCM power volume | perform a tool surface test, perform a RIH for setting job, perform a reset after completing setting job, or tool surface test 5 times | perform a tool surface test, perform a RIH for setting job, perform a reset after completing setting job, or tool surface test 5 times | perform a tool surface test, perform a RIH for setting job, perform a reset after completing setting job, or tool surface test 5 times | perform a tool surface test, perform a RIH for setting job, perform a reset after completing setting job, or tool surface test 5 times | perform a tool surface test, perform a RIH for setting job, perform a reset after completing setting job, or tool surface test 5 times |
PCM Recovery | Free recovery by SHARP RAZOR | Free recovery by SHARP RAZOR | Free recovery by SHARP RAZOR | Free recovery by SHARP RAZOR | Free recovery by SHARP RAZOR |